Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM1205
Message Memory mirror redundancy is lost. Check memory device at location(s) arg1 .
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response
Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Memory mirror lost on <location>. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM1206
Message Memory mirror redundancy is degraded. Check memory device at location arg1 .
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response
Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 2 (Warning)
800