Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
MEM1205
Message Memory mirror redundancy is lost. Check memory device at location(s) arg1 .
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response
Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Memory mirror lost on <location>. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
MEM1206
Message Memory mirror redundancy is degraded. Check memory device at location arg1 .
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response
Action
Review system logs for memory exceptions. Re-install memory at location
<location>
Category System Health (MEM = Memory)
Severity Severity 2 (Warning)
800