Reference Guide

MEM1016
Message Memory device at location arg1 is not installed correctly.
Arguments arg1 = location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed. Memory
size is reduced.
Recommended
Response
Action
Re-install the memory component. If the problem continues, contact support.
Category System Health (MEM = Memory)
Severity Severity 1 (Critical)
Trap/EventID 2265
LCD Message Memory <location> is not installed correctly. Re-install
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
MEM1017
Message Memory device at location arg1 is installed correctly.
Arguments arg1 = location
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (MEM = Memory)
Severity Severity 3 (Informational)
Trap/EventID 2267