Reference Guide
LOG507
Message Unable to allocated required CMC resources.
Detailed
Description
The operation did not complete successfully because of lack of memory or file
space in the CMC.
Recommended
Response
Action
Reset the CMC and retry the operation.
Category Configuration (LOG = Log event)
Severity Severity 1 (Critical)
No alerts are applicable for this message
LOG508
Message Unable to write to the network share.
Detailed
Description
The network share may be read-only or it may not have sufficient space for the
export operation.
Recommended
Response
Action
Verify the network share is not read-only and has sufficient space for exporting,
then retry the operation.
Category Configuration (LOG = Log event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
LOG509
Message Unable to run the command because the parameter value of arg1 exceeds the
maximum allowed number of arg2 characters.
Arguments arg1 = parameter name, arg2 = max parameter length
Detailed
Description
The command cannot be run because the value of the parameter identified in the
message exceeds the maximum length identified in the message.
Recommended
Response
Action
Enter a value for the parameter identified in the message that is equal to or less
than the maximum allowed characters.
Category Configuration (LOG = Log event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
772