ISM Event Messages
ISM0000
Message The iDRAC Service Module is started on the operating system (OS) of server.
Detailed
Description
The iDRAC Service Module is started on the OS of server.
Recommended
Response
Action
No response action is required.
Category Audit (ISM = iDRAC Service Module)
Severity Severity 3 (Informational)
No alerts are applicable for this message
ISM0001
Message The iDRAC Service Module detected a OS to iDRAC Pass-through in the arg1
mode. Switch the OS to iDRAC Pass-through to a USB NIC mode.
Arguments arg1 = mode
Detailed
Description
The iDRAC Service Module detected a OS to iDRAC Pass-through mode as
identified in the message. iDRAC Service Module will automatically connect to
iDRAC after the OS to iDRAC Pass-through is configured to the USB NIC mode.
Recommended
Response
Action
Configure OS to iDRAC Pass-through to the USB NIC mode by running the
commands: 1) racadm set idrac.os-bmc.PTMode usb-p2p 2) racadm set idrac.os-
bmc.UsbNicIpAddress <ip address> 3) racadm set idrac.os-bmc.adminstate
enabled
Category Audit (ISM = iDRAC Service Module)
Severity Severity 1 (Critical)
No alerts are applicable for this message
ISM0002
Message The OS to iDRAC Pass-through is disabled. The iDRAC Service Module is currently
enabling the OS to iDRAC Pass-through in the USB NIC mode.
Detailed
Description
The OS to iDRAC Pass-through mode is disabled. The iDRAC Service Module is
currently enabling the OS to iDRAC Pass-through mode in the USB NIC mode. This
operation is done only for the first run of iDRAC Service Module. If OS to iDRAC
Pass-through is disabled after this point of time, iDRAC Service Module will not be
able to connect to iDRAC until user enables the OS-iDRAC Pass-through in the
USB mode.