Reference Guide

Detailed
Description
The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been
assigned to the server identified in the message.
Recommended
Response
Action
No response action is required.
Category Configuration (IOV = IO Virtualization)
Severity Severity 3 (Informational)
Trap/EventID 10747
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC * *
IOV115
Message Unable to allocate arg1 WATTS for discovery of PCIE adapters.
Arguments arg1 = number of watts
Detailed
Description
The discovery process for PCIE adapters was unable to allocate the power required
to power on the PCIE adapters
Recommended
Response
Action
Using the Chassis Management Controller (CMC) RACADM command line
interface, run the command "racadm config -g cfgChassisPower -o
cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional
power supply.
Category Configuration (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Trap/EventID 10746
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
674