Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
IOV004
Message Unable to turn on PCIe adapter.
Detailed
Description
The chassis manager is unable to turn on the PCIe device because of one of the
following reasons: 1) PCIe device is not supported, 2) The device is not properly
inserted in the slot, 3) The device is not functioning properly, or 4) The device
power requirements exceed the power available for the slot.
Recommended
Response
Action
Make sure a supported PCIe device is used and that it is properly inserted in the
PCIe slot. For a list of supported devices, contact the service provider.
Category Configuration (IOV = IO Virtualization)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
IOV005
Message Chassis Management Controller (CMC) is not ready to run commands.
Detailed
Description
The Chassis Management Controller is not ready to run commands because the
chassis must be turned on.
Recommended
Response
Action
Turn on chassis and retry the command.
656