Reference Guide

IOID118
Message Unable to configure some or all I/O Identity settings based on current persistence
policy settings.
Detailed
Description
The iDRAC has applied I/O Identity Configuration on NIC and FC HBA devices. One
or more of the setting configuration operations did not complete successfully.
Recommended
Response
Action
Review the previous log entries and identify the devices that did not successfully
complete configuration operations. For the identified devices, do the following and
then restart the server: 1) Make sure the device is installed properly. 2) Make sure
the device has latest firmware installed. If the issue persists, contact your service
provider.
Category Configuration (IOID = IO Identity Optimization)
Severity Severity 2 (Warning)
Trap/EventID 10770
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
IOID119
Message FlexAddress is enabled on all NIC and FC HBA devices.
Detailed
Description
The FlexAddress feature is enabled on the system. The iDRAC will assign
FlexAddress defined MAC and WWN values to all the ports and/or partitions of
bNDCs and mezzanine adapters of the system.
Recommended
Response
Action
No response action is required.
Category Configuration (IOID = IO Identity Optimization)
Severity Severity 3 (Informational)
Trap/EventID 10771
652