Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
IOID113
Message Unable to configure the initiator properties of NIC arg1 Port arg2 .
Arguments arg1 = Controller, arg2 = Port
Detailed
Description
The initiator properties of the NIC port could not be configured because either
iSCSI or FCoE partition of the network port is not enabled, or the network
controller is not functioning.
Recommended
Response
Action
Make sure that the iSCSI or FCoE partition of the network port is enabled. Check
whether or not the network controller is working and then retry the operation.
Category Configuration (IOID = IO Identity Optimization)
Severity Severity 2 (Warning)
Trap/EventID 10770
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
IOID114
Message The target settings properties of the NIC arg1 Port arg2 are successfully configured.
Arguments arg1 = controller, arg2 = port
Detailed
Description
The target setting properties of the NIC port identified in the message are
successfully configured.
Recommended
Response
Action
No response action is required.
Category Configuration (IOID = IO Identity Optimization)
Severity Severity 3 (Informational)
649