Reference Guide
HWC8503
Message Communication to the control panel has been restored.
Detailed
Description
The communication between the Chassis Management Controller (CMC) and the
control panel is functioning normally.
Recommended
Response
Action
No response action is required.
Category System Health (HWC = Hardware Config)
Severity Severity 3 (Informational)
Trap/EventID 2331
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔* ✔*
HWC8504
Message The Chassis Management Controller (CMC) cannot communicate with the control
panel.
Detailed
Description
The control panel is not functioning normally. This could be because the Chassis
Management Controller (CMC) cannot communicate with the control panel or
because of a problem with the control panel hardware.
Recommended
Response
Action
Remove and reapply chassis input power. If problem persists, contact your service
provider.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
640