Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
HWC5001
Message arg1 is offline.
Arguments arg1 = name
Detailed
Description
None
Recommended
Response
Action
If unexpected, check presence, then re-install or reconnect.
Category System Health (HWC = Hardware Config)
Severity Severity 2 (Warning)
Trap/EventID 2330
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
HWC5002
Message A fabric mismatch detected on arg1 .
Arguments arg1 = name
Detailed
Description
The fabric type for the IOM and mezzanine cards must match. Once an IOM or
mezzanine card is inserted into the chassis, the fabric type is then set for the CMC
and the CMC will ensure that all subsequent IOMs and mezzanine cards match.
615