Reference Guide
Recommended
Response
Action
No response action is required.
Category System Health (HWC = Hardware Config)
Severity Severity 3 (Informational)
Trap/EventID 2331
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
HWC3006
Message Unable to QuickDeploy server in slot arg1 .
Arguments arg1 = slot number
Detailed
Description
There are not enough IPv4 addresses reserved for the servers in this chassis.
Therefore the newly inserted server could not be configured with the QuickDeploy
feature.
Recommended
Response
Action
Do the following: 1) Check the number of reserved IPv4 addresses for
QuickDeploy. 2) Modify it such that the newly inserted blade will obtain an IP
address for QuickDeploy. 3) Reseat the server to retry the QuickDeploy operation
or manually configure the network parameters for the server. (Note that some
chassis models may require a response at the LCD panel)
Category System Health (HWC = Hardware Config)
Severity Severity 2 (Warning)
Trap/EventID 2330
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔