Reference Guide
Recommended
Response
Action
Check presence, then re-install or reconnect.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
LCD Message Riser board cable or interconnect failure. Check connection
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔ ✔
CMC
HWC2012
Message A fabric mismatch detected on fabric arg1 with server in slot arg2 .
Arguments arg1 = name, arg2 = number
Detailed
Description
The fabric type on the server does not match that of the IO module.
Recommended
Response
Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or
mezzanine card.
Category System Health (HWC = Hardware Config)
Severity Severity 1 (Critical)
Trap/EventID 2329
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
600