Reference Guide
OMSA Event ID 2933
OMSA Trap ID 120300;150300,160300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
FLDC1028
Message OMSS Connection to Fluid Cache service is no longer present.
Detailed
Description
The communications connnection between OMSS and the Fluid Cache service is
no longer present.
Recommended
Response
Action
To reconnect OMSS to the Fluid Cache service: 1) Verify the Fluid Cache service is
running. To verify the service run the following command: "fldc --status". 2) Re-
establish the connect by running the following command: :"omconfig storage
fluidcache action=connect"
Category Storage (FLDC = Unknown)
Severity Severity 1 (Critical)
OMSA Event ID 2699
OMSA Trap ID 160400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
FLDC1029
Message There are not enough journal mirrors available for Fluid Cache to operate.
559