Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
FLDC1026
Message Caching is no longer degraded to write-through mode and is now operating in
write-back mode for Fluid Cache.
Detailed
Description
The caching mode has been restored back to write-back mode due to the
availability of additional PCIeSSD devices in the Fluid Cache configuration.
Recommended
Response
Action
No response action is required.
Category Storage (FLDC = Unknown)
Severity Severity 2 (Warning)
OMSA Event ID 2932
OMSA Trap ID 120300;150300;160300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
FLDC1027
Message Caching is no longer degraded to pass-through mode and is now operating in its
configured mode for Fluid Cache.
Detailed
Description
The caching mode has been restored back to the configured mode due to the
availability of additional PCIeSSD devices in the Fluid Cache configuration.
Recommended
Response
Action
No response action is required.
Category Storage (FLDC = Unknown)
Severity Severity 2 (Warning)
558