Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FLDC1013
Message The cached LUN with WWN = arg1 and path = arg2 for arg3 has had a failure.
Arguments arg1 = World Wide Name, arg2 = device pathname, arg3 = virtual disk name
Detailed
Description
The cached LUN identified in the message has had a failure to successfully perform
a read or write operation. The user application should now be seeing I/O failures
when trying to read or write to the Fluid Cache device at the path identified in the
message.
Recommended
Response
Action
Contact your service provider to diagnose the cause and assist in recovery process.
Category Storage (FLDC = Unknown)
Severity Severity 1 (Critical)
OMSA Event ID 2911
OMSA Trap ID 140400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FLDC1014
Message Replication of the cache device arg1 with WWN = arg2 and path = arg3 is
complete.
Arguments arg1 = physical device name, arg2 = World Wide Name, arg3 = device pathname
Detailed
Description
Replication of the cache device identified in the message is complete.
Recommended
Response
Action
No response action is required.