Reference Guide
Detailed
Description
The Enhanced Cooling Mode cannot be set because required power is not
available.
Recommended
Response
Action
Add PSUs with higher power capability or remove Chassis components such as I/O
Modules orservers until the power requirements have been lowered enough to
emable the Enhanced Cooling Mode, and then retry the operation.
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
FAN903
Message Cannot enable the Enhanced Cooling Mode because an unsupported fan is
inserted in the Chassis.
Detailed
Description
The Enhanced Cooling Mode cannot be enabled because an unsupported fan is
present in the Chassis.
Recommended
Response
Action
Insert a fan that is supported by the Chassis, and then retry the operation. For a list
of fans that are supported by Chassis, see the Chassis Management Controller
Users Guide.
Category Configuration (FAN = Fan Event)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
527