Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
FAN0023
Message Unable to read the arg1 sensor value.
Arguments arg1 = sensor name
Detailed
Description
The fan sensor identified in the message has failed or the fan has failed.
Recommended
Response
Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the
system to check if the fan is working properly, 2) Replace the system board if the
fan sensor has failed. 3) If the issue persists, contact your service provider.
Category System Health (FAN = Fan Event)
Severity Severity 2 (Warning)
OMSA Event ID 5101
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
FAN0024
Message The arg1 sensor returned to a normal state with a value of arg2 RPM.
Arguments arg1 = sensor name, arg2 = fan speed
Detailed
Description
The sensor identified in the message has returned to a normal state.
519