FAN0002
Message Fan arg1 RPM is greater than the upper warning threshold.
Arguments arg1 = number
Detailed
Description
The fan is not performing optimally. The fan may be installed improperly or may be
failing.
Recommended
Response
Action
Remove and re-install the fan at the next scheduled service window. If the issue
persists, contact technical support. Refer to the product documentation to choose
a convenient contact method.
Category System Health (FAN = Fan Event)
Severity Severity 2 (Warning)
Trap/EventID 2154
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
FAN0003
Message Fan arg1 RPM is greater than the upper critical threshold.
Arguments arg1 = number
Detailed
Description
The fan is not performing optimally. The fan may be installed improperly or may be
failing.