Reference Guide

ENC5
Message Redundancy on arg1 is degraded
Arguments arg1 = Enclosure Name
Detailed
Description
One or more of the enclosure components has failed. For example, a fan or power
supply may have failed. Although the enclosure is currently operational, the failure
of additional components could cause the enclosure to fail.
Recommended
Response
Action
Identify and replace the failed component. To identify the failed component, select
the enclosure in the tree view and click the Health subtab. Any failed component
will be identified with a red X on the enclosures Health subtab. Alternatively, you
can select the Storage object and click the Health subtab. The controller status
displayed on the Health subtab indicates whether a controller has a failed or
degraded component. See the enclosure documentation for information on
replacing enclosure components and for other diagnostic information.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
OMSA Event ID 2122
OMSA Trap ID 130500
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC6
Message Communication timeout on arg1 .
Arguments arg1 = Enclosure Name
Detailed
Description
The controller is unable to communicate with an enclosure. There are several
reasons for communication loss. For example, there may be a bad or loose cable.
An unusual amount of I/O may also interrupt communication with the enclosure.
In addition, communication loss may be caused by software, hardware, or firmware
problems, bad or failed power supplies, and enclosure shutdown.
501