Reference Guide

ENC33
Message Redundancy on arg1 is normal.
Arguments arg1 = Enclosure Name
Detailed
Description
Data redundancy has been restored to an enclosure that previously suffered a loss
of redundancy.
Recommended
Response
Action
This alert is provided for informational purposes.
Category Storage (ENC = Storage Enclosr)
Severity Severity 3 (Informational)
Trap/EventID 4339
OMSA Event ID 2124
OMSA Trap ID 130400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC4
Message arg1 firmware mismatch.
Arguments arg1 = Enclosure Name
Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both
modules have the same version of the firmware. This alert may be caused when
you attempt to insert an EMM module that has a different firmware version than an
existing module.
Recommended
Response
Action
Download the same version of the firmware to both EMM modules.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
499