Reference Guide
ENC28
Message Enclosure Management Module (EMM) firmware version mismatch detected in
arg1 . arg2 arg3 .
Arguments arg1 = enclosure name, arg2 = EMM 0 version, arg3 = EMM 1 version
Detailed
Description
The firmware on the EMM modules is not the same version. Both modules must
have the same firmware version. This message is caused when you attempt to
insert an EMM module that has a different firmware version than an existing
module.
Recommended
Response
Action
Upgrade to the same version of the firmware on both EMM modules.
Category Storage (ENC = Storage Enclosr)
Severity Severity 2 (Warning)
Trap/EventID 4338
OMSA Event ID 2311
OMSA Trap ID 85300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
ENC29
Message arg1 temperature has returned to normal.
Arguments arg1 = Enclosure Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response
Action
No response action is required.
Category Storage (ENC = Storage Enclosr)
Severity Severity 3 (Informational)