Reference Guide

ENC25
Message arg1 has a hardware error.
Arguments arg1 = enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state.
Recommended
Response
Action
Verify the health of the enclosure and its components. See the storage hardware
documentation for more information. Contact technical support.
Category Storage (ENC = Storage Enclosr)
Severity Severity 1 (Critical)
Trap/EventID 4337
OMSA Event ID 2301
OMSA Trap ID 85400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC26
Message arg1 is not responding.
Arguments arg1 = enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state. It is not
responding to storage management commands or there is a connectivity problem
between the controller and enclosure.
Recommended
Response
Action
Verify the health of the enclosure and its components. See the hardware
documentation to for more information. Contact technical support.
Category Storage (ENC = Storage Enclosr)
Severity Severity 1 (Critical)
Trap/EventID 4337
493