Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
ENC19
Message arg1 has failed.
Arguments arg1 = Enclosure Management Module Name
Detailed
Description
An Enclosure Management Module (EMM) has failed. The failure may be caused by
a loss of power to the EMM. The EMM self-test may also have identified a failure.
There may also be a firmware problem or a multi-bit error.
Recommended
Response
Action
Reseat the Enclosure Management Module (EMM). See the storage hardware
documentation for information on replacing the EMM. Replace the EMM. Contact
technical support if the issue persists.
Category Storage (ENC = Storage Enclosr)
Severity Severity 1 (Critical)
Trap/EventID 4337
OMSA Event ID 2293
OMSA Trap ID 85400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
ENC2
Message arg1 was removed..
Arguments arg1 = Enclosure Management Module Name
Detailed
Description
An Enclosure Management Module (EMM) was removed.
Recommended
Response
Action
Reinsert the Enclosure Management Module (EMM). See the storage hardware
documentation for information on replacing the EMM.
489