Reference Guide

Detailed
Description
This alert is provided for informational purposes.
Recommended
Response
Action
No response action is required.
Category Storage (ENC = Storage Enclosr)
Severity Severity 3 (Informational)
Trap/EventID 4339
OMSA Event ID 2291
OMSA Trap ID 85100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
ENC18
Message Communication with arg1 was lost.
Arguments arg1 = enclosure name
Detailed
Description
The controller has lost communication with an Enclosure Management Module
(EMM). The cables may be loose or defective.
Recommended
Response
Action
Make sure the cables are attached securely. See the storage hardware
documentation for more information on checking the cables. Reboot the system.
Category Storage (ENC = Storage Enclosr)
Severity Severity 1 (Critical)
Trap/EventID 4337
OMSA Event ID 2292
OMSA Trap ID 85400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
488