Reference Guide
Severity Severity 3 (Informational)
Trap/EventID 10635
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
DIS106
Message Unable to start the AutoConfig file import operation, because an invalid shutdown
type was specified in the DHCP scope option field where the VendorID=iDRAC.
Detailed
Description
The AutoConfig import file operation could not be successfully completed,
because the shutdown type (-d) specified in the DHCP scope option field where
the VendorID=iDRAC is incorrect.
Recommended
Response
Action
Enter a valid shutdown type in the DHCP scope option field where the
VendorID=iDRAC using (-d <0 or 1>) where 0 = Graceful shutdown and 1 = Forced
shutdown.
Category Configuration (DIS = Auto-Discovery)
Severity Severity 3 (Informational)
Trap/EventID 10635
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
DIS107
Message Unable to start the AutoConfig file import operation, because an invalid AutoConfig
time-to-wait value is specified in the DHCP scope option field where the
VendorID=iDRAC.