Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
DIAG8158
Message arg1 Drive arg2 - S/N arg3 , incorrect status = arg4 \n arg5 .
Arguments arg1 = Backplane|Expander|RD1000, arg2 = Drive Location, arg3 = Serial Number,
arg4 = 80000000000000??, arg5 = Error Reason
Detailed
Description
A device failed a command and testing cannot complete.
Recommended
Response
Action
Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
DIAG8160
Message PERC Battery arg1 - incorrect status = arg2 \n arg3 .
Arguments arg1 = PERC Controller Location, arg2 = 80000000000000??, arg3 = Error
Reason
Detailed
Description
Recommended
Response
Action
"If <Error Reason> is (Battery missing or disconnected) then check the battery cable
to the PERC controller. If <Error Reason> is (Replace battery pack) then replace
battery pack. If <Error Reason> is (Remaining capacity low) then battery pack may
need to be replaced soon."
Category Storage (DIAG = Diagnostic)
Severity Severity 2 (Warning)
458