Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0151
Message Hard Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 .
Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = 80000000000000??, arg4 =
Error Reason
Detailed
Description
Recommended
Response
Action
SMART Predictive Failure indicates the hard drive has failed SMART and maybe
nearing the end of its life. Other types of <Error Reason> in this category may
indicate an intermittent or firmware problem, rerun the test again. Desktops,
servers: Check the hard disk drive cables and connections. All systems: If error
persists, make sure that hard disk drive firmware and BIOS are current. The
<80000000000000??> value is an EFI error code returned by the driver.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
DIAG0152
Message Optical Drive arg1 - Incorrect status = arg2 arg3 .
Arguments arg1 = Nth Drive, arg2 = Hex, arg3 = Error Reason
Detailed
Description
Recommended
Response
Action
Check the drive cables and connections. If error persists, make sure that drive
firmware and BIOS are current. The <80000000000000??> value is an EFI error
code returned by the driver.
Category Storage (DIAG = Diagnostic)
429