Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
DIAG0151
Message Hard Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 .
Arguments arg1 = Drive Location, arg2 = Serial Number, arg3 = 80000000000000??, arg4 =
Error Reason
Detailed
Description
Recommended
Response
Action
SMART Predictive Failure indicates the hard drive has failed SMART and maybe
nearing the end of its life. Other types of <Error Reason> in this category may
indicate an intermittent or firmware problem, rerun the test again. Desktops,
servers: Check the hard disk drive cables and connections. All systems: If error
persists, make sure that hard disk drive firmware and BIOS are current. The
<80000000000000??> value is an EFI error code returned by the driver.
Category Storage (DIAG = Diagnostic)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
DIAG0152
Message Optical Drive arg1 - Incorrect status = arg2 arg3 .
Arguments arg1 = Nth Drive, arg2 = Hex, arg3 = Error Reason
Detailed
Description
Recommended
Response
Action
Check the drive cables and connections. If error persists, make sure that drive
firmware and BIOS are current. The <80000000000000??> value is an EFI error
code returned by the driver.
Category Storage (DIAG = Diagnostic)
429