Reference Guide

CTL88
Message arg1 firmware does not match the firmware of its peer controller.
Arguments arg1 = controller name
Detailed
Description
The firmware running on the controller identified in the message does not match
the firmware version of its peer controller. This can cause issues in a fault tolerant
setup.
Recommended
Response
Action
Make sure each controller is using the same firmware by updating the firmware of
the identified controller.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
CTL89
Message arg1 is no longer fault tolerant because the peer controller is not available.
Arguments arg1 = controller name
Detailed
Description
The peer controller is no longer active in this fault tolerant pair. This can be a
temporary situation.
Recommended
Response
Action
Check the chassis log for issues with the peer controller. If the peer controller does
not resume normal operations after 5 minutes contact your service provider.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
406