Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL76
Message A configuration command could not be committed to disk on arg1
Arguments arg1 = Controller name
Detailed
Description
The controller encountered errors while applying the configuration on the physical
disks. The configuration command applied has not taken effect.
Recommended
Response
Action
Re-issue the failed configuration command or try with a different set of physical
disks. Contact technical support if the problem persists.
Category Storage (CTL = Storage Contr)
Severity Severity 1 (Critical)
Trap/EventID 4329
OMSA Event ID 2401
OMSA Trap ID 75400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL77
Message Flash of new firmware image(s) completed on arg1
Arguments arg1 = Controller Name
398