Reference Guide

Arguments arg1 = Controller name
Detailed
Description
The controller has detected a change in the storage configuration between since
its last shut down. This can generally happen if some configured physical disks are
removed from the system when the system was shutdown.
Recommended
Response
Action
Shut down the system. Re-insert the removed physical disks and re-start the
system.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
OMSA Event ID 2361
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
CTL62
Message arg1 on arg2 has missing drives and will go offline at boot.
Arguments arg1 = VD names, arg2 = Controller name
Detailed
Description
Physical disk(s) have been removed from a virtual disk. The virtual disk will be in
Failed state during the next system reboot. This alert is provided for informational
purposes.
Recommended
Response
Action
No response action is required.
Category Storage (CTL = Storage Contr)
Severity Severity 3 (Informational)
Trap/EventID 4331
OMSA Event ID 2362
OMSA Trap ID 75100
388