Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL58
Message arg1 SAS SMP communications error arg2
Arguments arg1 = Controller name, arg2 = args
Detailed
Description
The text for this alert is generated by the firmware and can vary depending on the
situation. The reference to SMP in this text refers to SAS Management Protocol.
Recommended
Response
Action
There may be a SAS topology error. See the hardware documentation for
information on correct SAS topology configurations. There may be problems with
the cables such as a loose connection or an invalid cabling configuration. See the
Cables Attached Correctly section for more information on checking the cables.
See the hardware documentation for information on correct cabling
configurations. Verify that the firmware version is supported.
Category Storage (CTL = Storage Contr)
Severity Severity 1 (Critical)
Trap/EventID 4329
OMSA Event ID 2356
OMSA Trap ID 75400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL59
Message arg1 SAS expander error: arg2
385