Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔ ✔* ✔
CTL50
Message The arg1 NVRAM has corrupt data.
Arguments arg1 = Controller name
Detailed
Description
The NVRAM has corrupt data. The controller is unable to correct the situation.
Recommended
Response
Action
Replace the controller.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
OMSA Event ID 2328
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL51
Message arg1 SAS port report: arg2
Arguments arg1 = Controller name, arg2 = message
Detailed
Description
The text for this message is generated by the controller during runtime and can
vary depending on the situation.
Recommended
Response
Action
Make sure the SAS cables attached to the enclosure/backplane are attached
securely. Refer to the storage hardware documentation for more information on
checking the cables. Contact technical support if the issue persists.
Category Storage (CTL = Storage Contr)
380