Reference Guide
Recommended
Response
Action
No response action is required as the controller is taking the required corrective
action. However, If this message is generated often (such as during each reboot),
then replace the controller.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
OMSA Event ID 2327
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL5
Message Bad block replacement error on arg1 .
Arguments arg1 = Controller name
Detailed
Description
A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with
"Replacement," "Sense," or "Medium" Error for more information.
Recommended
Response
Action
See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for
more information.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
Trap/EventID 4330
OMSA Event ID 2146
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
379