Reference Guide
Detailed
Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data
corruption may occur..
Recommended
Response
Action
Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a
part of the controller battery pack. Refer to the storage hardware documentation
for information on replacing the DIMM.
Category Storage (CTL = Storage Contr)
Severity Severity 1 (Critical)
Trap/EventID 4329
OMSA Event ID 2320
OMSA Trap ID 75400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL47
Message Single-bit ECC error on arg1 .
Arguments arg1 = Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data
corruption may occur. The DIMM must be replaced immediately.
Recommended
Response
Action
Replace the DIMM immediately. The DIMM is a part of the controller battery pack.
Refer to your hardware documentation for information on replacing the DIMM.
Category Storage (CTL = Storage Contr)
Severity Severity 1 (Critical)
Trap/EventID 4329
OMSA Event ID 2321
OMSA Trap ID 75400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
377