Reference Guide
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL42
Message Enclosure Management Module (EMM) hot plug is not supported on arg1 .
Arguments arg1 = Controller name
Detailed
Description
An attempt to hot plug an Enclosure Management Module (EMM) has been
detected.
Recommended
Response
Action
If the new enclosure and its device are not detected by the operating system, try
restarting your system to verify the newly attached enclosure and its sub-
components are detected. See the hardware documentation for more information.
Category Storage (CTL = Storage Contr)
Severity Severity 3 (Informational)
Trap/EventID 4331
OMSA Event ID 2304
OMSA Trap ID 75100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
CTL43
Message Diagnostic message arg1 from arg2
374