Reference Guide
OMSA Event ID 2411
OMSA Trap ID 75100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
CTL215
Message Redundant path disconnected on arg1 .
Arguments arg1 = Controller Name
Detailed
Description
The controller identified in the message has two connectors that are connected to
the same enclosure. The communication path on one connector has lost
connection with the enclosure. The communication path on the other connector
is reporting this loss.
Recommended
Response
Action
Make sure both the cables are securely attached to the enclosure and controller.
FOr more information about connecting the cables to the enclosure, see the
Cables Attached Correctly section in the PERC Users Guide. Also, make sure both
Enclosure Management Modules (EMMs) are healthy.
Category Storage (CTL = Storage Contr)
Severity Severity 2 (Warning)
OMSA Event ID 2250
OMSA Trap ID 75300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔
CMC
358