Reference Guide

CPU0802
Message A predictive failure detected on CPU arg1 voltage regulator module.
Arguments arg1 = number
Detailed
Description
System performance may be degraded or the system may fail to operate.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 2 (Warning)
Trap/EventID 2242
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
CPU0803
Message The power input for CPU arg1 voltage regulator module is lost.
Arguments arg1 = number
Detailed
Description
System performance may be degraded or the system may fail to operate.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message Lost power input for CPU <number> voltage regulator module. Reseat module
332