Reference Guide
Recommended
Response
Action
Check system and operating system logs for exceptions. If no exceptions found,
remove input power, reinstall the processor, then apply input power.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU bus parity error detected. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
CPU0703
Message CPU bus initialization error detected.
Detailed
Description
System event log and OS logs may indicate that the exception is external to the
processor.
Recommended
Response
Action
1) Check system and operating system logs for exceptions. If no exceptions are
found continue. 2) Turn system off and remove input power for one minute. Re-
apply input power and turn system on. 3) Make sure the processor is seated
correctly. 4) If the issue still persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU bus initialization error detected. Power cycle system
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
329