Reference Guide
CPU0025
Message CPU arg1 terminator is absent.
Arguments arg1 = number
Detailed
Description
System is unable to boot or may run in a degraded state.
Recommended
Response
Action
Check presence and reinstall the terminator.
Category System Health (CPU = Processor)
Severity Severity 2 (Warning)
Trap/EventID 2242
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
CPU0700
Message CPU arg1 initialization error detected.
Arguments arg1 = number
Detailed
Description
System BIOS was unable to boot the processor.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health (CPU = Processor)
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> initialization error detected. Power cycle system
327