Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
CMC8604
Message The FRU on storage sled arg1 is not functioning.
Arguments arg1 = slot number
Detailed
Description
The FRU on the storage sled specified in the message is not functioning or CMC is
unable to read it.
Recommended
Response
Action
Do the following: 1) Reinsert the specified storage sled or virtual reseat the sled 2)
Reset CMC and wait for a few minutes for the CMC to finish restarting. If the issue
persists, contact your service provider.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8605
Message The chassis health state is no longer OK and is currently arg1 .
Arguments arg1 = health state
Detailed
Description
The chassis health state is no longer OK and is currently the state identified in the
message. Actions should be taken to resolve any outstanding issues so that the
chassis health state will return to OK.
Recommended
Response
Action
Review the Chassis log or the Chassis Management Controller(CMC) SEL log for
any outstanding issue(s) and resolve any issues found by performing the
recommended response action for each issue found. If the issue persists, export
the chassis log and CMC SEL log and contact your support provider.
Category Audit (CMC = Chassis Management Controller)
315