Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8525
Message The FRU on the sleeve arg1 is not functioning.
Arguments arg1 = slot number
Detailed
Description
The FRU on the sleeve specified in the message is not functioning or CMC is
unable to read it.
Recommended
Response
Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server.
2) Reset CMC and wait for a few minutes. If the issue persists, contact your service
provider.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8526
Message Unable to retrieve the server- arg1 CPU information.
Arguments arg1 = slot number
Detailed
Description
CMC is unable to obtain the CPU information from the server specified in the
message. This occurs if there is no communication between CMC and iDRAC.
288