Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8518
Message Detecting Double height server in slot arg1 but the iDRAC in bottom slot arg2 is
also responding.
Arguments arg1 = slot number, arg2 = slot number
Detailed
Description
the Double height server identified in the message is detected in the top slot.
However, the bottom slot is also responding which should not occur if a double
height server is inserted.
Recommended
Response
Action
Do the following: 1) Remove the server identified in the message. 2) Restart the
CMC and wait for the CMC to complete the start up process. 3) Reinsert the server
identified in the message. If the problem persists, contact your service provider.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8519
Message The LOM riser FRU for slot arg1 FRU ID arg2 is not functioning.
Arguments arg1 = slot number, arg2 = fru id
Detailed
Description
FRU of the LOM riser specified in the message is not functioning or CMC is unable
to read it.
Recommended
Response
Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server.
2) Reset CMC and wait for a few minutes. If the issue persists, contact your service
provider.
Category System Health (CMC = Chassis Management Controller)
284