Reference Guide
Detailed
Description
The I/O module may have taken more time to boot than was expected or the I/O
module did not boot.
Recommended
Response
Action
Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and
retry the operation. Otherwise, reinsert the I/O Module and retry the operation. If
the problem persists, contact technical support.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 2546
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8517
Message A double height server is detected in slot arg1 , however the server is not detected
in the bottom slot.
Arguments arg1 = slot number
Detailed
Description
A double height server is detected in slot specified in the message, however the
server is not detected in the bottom slot. This occurs if the server is not correctly
inserted into the chassis.
Recommended
Response
Action
Remove the server from the chassis, check for any broken or bent pins at the rear
of the server. If there is no damage, reinsert the server into the chassis.
Category System Health (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 2545
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
283