Reference Guide
Detailed
Description
The Extended Storage feature is not activated if the removable flash media SD card
on the secondary CMC does not respond within 90 seconds after activation is
initiated.
Recommended
Response
Action
Do the following and retry the operation: 1) In the CMC Web interface, go to
Chassis Controller > Flash Media > Configuration, and verify if the SD card on
secondary CMC displays errors. 2) If errors are displayed, execute the following
racadm command: "racadm cmcchangeover". 3) Repair the removable flash media
SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair
Active Controller Media in the CMC Web interface. Repairing is only allowed on the
SD card of the primary CMC. If the problem persists, replace the card.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 1 (Critical)
Trap/EventID 8689
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8513
Message The Extended Storage feature activation on the secondary CMC timed out. The
feature is being returned to single CMC mode.
Detailed
Description
The Extended Storage feature activation on the secondary CMC timed out. If the
media on Standby CMC doesnt respond within 90 seconds of confirming activation
the feature returns to single CMC mode.
Recommended
Response
Action
Do the following and retry the operation: 1) In the CMC Web interface, go to
Chassis Controller > Flash Media > Configuration, and verify if the SD card on
secondary CMC displays errors. 2) If errors are displayed, execute the following
racadm command: "racadm cmcchangeover". 3) Repair the removable flash media
SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair
Active Controller Media in the CMC Web interface. Repairing is only allowed on the
SD card of the primary CMC. If the problem persists, replace the card.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 8690
281