Reference Guide
Severity Severity 1 (Critical)
Trap/EventID 8689
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8511
Message Unable to synchronize the data in the Extended Storage removable flash media in
the primary and secondary CMCs.
Detailed
Description
The data on the Extended Storage removable flash media SD cards is not
synchronized when the CMC is unable to determine which card has the latest data.
Recommended
Response
Action
Disable and then enable the Extended Storage feature. Using racadm, execute the
following commands: "racadm feature -d -c Extended Storage" to disable and then
"racadm -a -c Extended Storage" to enable the feature. NOTE: All the data on the
removable flash media SD card is erased when the feature is disabled.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Trap/EventID 8690
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔*
CMC8512
Message The Extended Storage feature activation timed out. The feature is not active.
280