Reference Guide

Category Audit (CMC = Chassis Management Controller)
Severity Severity 3 (Informational)
Trap/EventID 8691
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
CMC8508
Message Unable to synchronize the primary and secondary CMC removable flash media and
the Extended Storage feature is not available.
Detailed
Description
The Extended Storage feature is not activated if the removable flash media SD Card
on the secondary CMC is not functioning properly.
Recommended
Response
Action
Do the following and retry the operation: 1) In the CMC Web interface, go to
Chassis Controller > Flash Media > Configuration, and verify if the SD card on
secondary CMC displays errors. 2) If errors are displayed, execute the following
racadm command: "racadm cmcchangeover". 3) Repair the removable flash media
SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair
Active Controller Media in the CMC Web interface. Repairing is only allowed on the
SD card of the primary CMC. If the problem persists, replace the card.
Category Audit (CMC = Chassis Management Controller)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
278