Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
CBL0005
Message Backplane arg1 arg2 connector incorrectly connected to the motherboard SATA
controller.
Arguments arg1 = bay ID, arg2 = connector name
Detailed
Description
The backplane connector identified in the message is incorrectly connected to the
motherboard SATA controller.
Recommended
Response
Action
Make sure the cable identified in the message is cabled correctly. If the issue
persists, contact your service provider.
Category System Health (CBL = Cable)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
CBL0006
Message Unsupported backplane arg1 configuration: Multiple RAID controllers cannot be
connected to the same backplane.
Arguments arg1 = bay ID
Detailed
Description
Each server model only supports a certain set of backplane configurations. For
unified backplanes or split mode capable backplanes that are in unified mode,
multiple controllers cannot be connected to the same backplane. In unified
backplane situations any controller besides the first will not be operational.
269