Reference Guide
Severity Severity 2 (Warning)
No alerts are applicable for this message
BIOS022
Message Cannot set the BIOS password. Password is disabled due to a jumper setting on the
motherboard.
Detailed
Description
The BIOS password is disabled in the hardware using a jumper and can not be set.
See the system owners manual for jumper location.
Recommended
Response
Action
Change the jumper setting on the system board to enable changing the BIOS
password.
Category Configuration (BIOS = BIOS Management)
Severity Severity 2 (Warning)
No alerts are applicable for this message
BIOS023
Message Cannot perform the operation due to an unknown error in iDRAC.
Detailed
Description
An unrecoverable error occurred in the operation while communicating with
iDRAC.
Recommended
Response
Action
Retry the operation. If the issue continues, reset the iDRAC.
Category Configuration (BIOS = BIOS Management)
Severity Severity 2 (Warning)
No alerts are applicable for this message
BIOS024
Message The set operation did not complete successfully as the attribute is read-only.
Detailed
Description
The operation cannot run as the attribute value cannot be modified.
Recommended
Response
Action
For more information on the attribute, see Lifecycle Controller-Remote Services
documentation.
Category Configuration (BIOS = BIOS Management)
Severity Severity 2 (Warning)
No alerts are applicable for this message
255