Reference Guide
OMSA Trap ID 115100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
BAT1033
Message The battery on arg1 was removed.
Arguments arg1 = controller name
Detailed
Description
The controller cannot communicate with the battery. Either the battery was
removed, or the contact point between the controller and the battery is degraded.
Recommended
Response
Action
Make sure that the battery is present and properly connected. If the battery is
present, wait for a few minutes and re-check if the battery is detected. If the
contact point between the battery and the controller is degraded, you must replace
the battery, the controller, or both. Refer to the storage hardware documentation
for information on how to safely access, or remove. Contact technical support if
the issue persists.
Category Storage (BAT = Battery Event)
Severity Severity 2 (Warning)
Trap/EventID 4274
OMSA Event ID 2174
OMSA Trap ID 115300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔
242