Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
BAT1028
Message The battery voltage on arg1 is low.
Arguments arg1 = controller name
Detailed
Description
The controller battery voltage is low. This may indicate that the battery is no longer
protecting the controller cache.
Recommended
Response
Action
The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Category Storage (BAT = Battery Event)
Severity Severity 2 (Warning)
Trap/EventID 4274
OMSA Event ID 2145
OMSA Trap ID 115300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
BAT1029
Message The battery on arg1 can no longer recharge.
Arguments arg1 = controller name
Detailed
Description
The controller battery cannot recharge. The battery may have already recharged
the maximum number of times or the battery charger may not be working.
Recommended
Response
Action
Contact technical support.
Category Storage (BAT = Battery Event)